                    Contact us
                    • Guangzhou Rong 'an Fire Equipment Co., LTD


                      Mr. Chen's telephone number:13928768802


                      Mr. Huang's telephone number:13711155165


                      Landline telephone:Landline telephone:020-31143089


                      Fax:020-31143992


                      E-mail:1851885478@qq.com


                      Website:http://www.butlerbelt.com.cn


                      Address: 15 Yongfeng Road, Shawan Town, Panyu District, Guangzhou City, Guangdong Province


                    News Detail
                    • Differences between internal and external storage pressures of heptafluoropropane
                      categories of news:Corporate news   Author:handler    Published on:2016-12-194    Text:【big】【medium】【small

                      The gas fire extinguishing system is divided into two types: pipe network and no pipe network. The pipe network includes internal storage pressure and external storage pressure. Today, we will talk about the differences between the internal storage pressure and external storage pressure of HFC-227ea.

                      First, transmission distance:

                      In general, the transmission distance of 2.5mpa pressure class pipeline is less than or equal to 32m, the transmission distance of 4.2mpa pressure class pipeline is less than or equal to 55m, and the transmission distance of 5.6mpa pressure class pipeline is less than or equal to 80m. The transmission distance greatly limits the application of HFC-227ea fire extinguishing system. The birth of external storage pressure is a good solution to solve this problem. The system action, fire extinguisher group, fire extinguishing agent group by special inflator cylinder group according to its stamping and conveying of HFC-227EA reagent design pressure is 4.2MPa, the maximum transport distance can be more than 240m.

                      Here we look at the parameters of external storage pressure:

                      According to the current national standard, the filling density of HFC-227ea fire extinguishing system with internal storage pressure is: 2.5MPa system should not be greater than 1120kg/m3 (steel welded gas cylinder); 4.2MPa system shall not be greater than 950kg/m3 (steel welded gas cylinder); 5.6MPa system should not be larger than 1080kg/m3 (steel seamless cylinder). 4.2MPa external storage pressure system shall not be greater than 1250kg/m3.

                      Technical parameters:

                      System main technical parameters

                      System implementation standard

                      Q/RXF 1-2014

                      Storage pressure (20℃, MPa)

                      0.3

                      Extinguishing agent cylinder group volume (L)

                      90

                      120

                      150

                      180

                      System injection time (s)

                      ≤10

                      Maximum filling rate of extinguishing agent(Kg/m3

                      1250

                      Operating temperature of the system (° C)

                      0~50

                      System working pressure (20℃) (MPa)

                      4.2

                      System maximum working pressure (MPa)

                      5.3

                      Temperature (℃)

                      pressure Mpa (20 ° C)

                      Power supply

                      Design temperature

                      Service temperature

                      Fire extinguishing agent bottle group

                      Nitrogen drive bottle set

                      Main electricity

                      Backup power

                      0~50

                      0~50

                      0.3

                      13.5

                      AC

                      220v

                      DC

                      24V

                       

                      Bottle group name

                      Model Specification (L)

                      Storage pressure (20℃)

                      Nitrogen starting bottle set

                      8L

                      6MPa

                      Nitrogen power cylinder set

                      70L

                      13.5MPa

                      Fire extinguishing agent bottle group

                      90

                      120

                      150

                      180

                      0.3MPa

                      Finally, the nitrogen power bottle group is added to the external pressure storage system, which increases a pushing pressure to the delivery of the agent, so the transmission distance is relatively long.

                      The above articles are organized and published by Guangzhou Rong 'an Fire Equipment Co., LTD.

                      Share with:
                      Number of clicks:10226  Update time:2016-12-19  【Print this page】  【CLOSE